Concrete Technology
Concrete is a system of substitutions: every change to the water, the cement, the admixture or the aggregate ripples through strength, workability and durability. This guide answers the technology questions that decide mix behaviour — why the water-cement ratio dominates strength (Abrams' law), what a superplasticizer does and does not do, when fly ash or GGBS helps, and what separates M20 from M50 beyond the number.
The 10 most-asked questions — click any question for the answer, and the clause it rests on
B-1
What is the difference between nominal mix and design mix?
What is the difference between nominal mix and design mix?
Nominal mix (e.g. 1:2:4 by volume) is a prescriptive recipe using assumed material qualities. Design mix (per IS 10262) is a performance recipe derived for the project’s actual materials, exposure condition and target workability. IS 456:2000 requires design mix for all grades M20 and above and for all durable structures; nominal mix is permitted only for small non-structural volumes. Try the calculator: Nominal Mix.
Reference: IS 456:2000 Cl. 9.3 & 10 · IS 10262:2019
B-2
What is Water-Cement Ratio and why does it matter for strength?
What is Water-Cement Ratio and why does it matter for strength?
w/c is the mass ratio of free water (excluding aggregate absorption) to cement. It controls strength, permeability and durability — not the cement content alone. IS 456:2000 Table 5 caps w/c for each exposure condition (0.55 for RCC under mild exposure, down to 0.45 for very severe and 0.40 for extreme exposure). Lower w/c → higher strength and lower permeability, but workability suffers unless compensated by plasticizer. Try the calculator: Water–Cement Ratio.
Reference: IS 456:2000 Cl. 8.2 & Table 5 · Abrams' law
B-3
How do admixtures affect concrete performance?
How do admixtures affect concrete performance?
Plasticizers (PCE-based) reduce mixing water by 12–25% at a given workability; superplasticizers by 25–40%. Retarders delay setting in hot weather or long hauls. Accelerators speed early strength for repairs and pre-stress. Air-entraining agents protect against freeze-thaw. The dosage is brand-specific and must be checked against IS 9103 limits, and the same brand/source should be used throughout the project to avoid incompatibility shocks.
Reference: IS 9103:1999 · ACI 212.3R
B-4
What is the role of supplementary cementitious materials (SCMs)?
What is the role of supplementary cementitious materials (SCMs)?
SCMs like fly ash (PFA), GGBS and silica fume replace part of the cement in the binder. They reduce heat of hydration (useful in mass pours), refine the pore structure (lower permeability) and improve long-term durability. The trade-off is slower early-age strength. IS 3812 (fly ash), IS 12089 (GGBS) and IS 15388 (silica fume) prescribe the use limits.
Reference: IS 3812 · IS 12089 · IS 15388 · IS 456:2000 Cl. 5.2
B-5
What is the difference between PPC, OPC and PSC cement?
What is the difference between PPC, OPC and PSC cement?
OPC (Ordinary Portland Cement, IS 269) is neat clinker + gypsum. PPC (Portland Pozzolana Cement, IS 1489) substitutes 15–35% fly ash and gains strength more slowly but is denser and more durable at later ages. PSC (Portland Slag Cement, IS 455) substitutes GGBS, similar profile. For marine / sulphate exposure, PPC or PSC performs better; for early-strength pre-stress, OPC 53 grade is preferred.
Reference: IS 269 · IS 1489 (Part 1 & 2) · IS 455
B-6
How is aggregate grading controlled and why does it matter?
How is aggregate grading controlled and why does it matter?
Aggregate grading — the distribution of particle sizes — controls water demand, paste content and pumpability. IS 383 specifies grading envelopes for fine aggregate (Zone II is the typical target) and nominal single-sized coarse aggregate (10 mm, 20 mm, 40 mm). Incorrect grading increases water demand by 5–15%, raises shrinkage and reduces pump pressure margin. Sieve testing at least once per lot.
Reference: IS 383:2016 Tables 4–13 · IS 2386 (Part 1)
B-7
What is the significance of the slump test?
What is the significance of the slump test?
Slump is a workability indicator, not a strength measure. Target slump depends on the placement method: 25–75 mm for chhabeena/manual compaction in slabs, 75–100 mm for normal vibration, 100–150 mm with pumped concrete, 150–180 mm for congested heavily-reinforced sections. Always confirm slump at point of discharge and also at pour when the transit time is significant.
Reference: IS 1199 (Part 2):2018 · IS 456:2000 Cl. 13.2
B-8
What is bleeding in concrete and how is it controlled?
What is bleeding in concrete and how is it controlled?
Bleeding is the upward migration of free water to the surface after placement. A little is normal (1–2% of mix water); excessive bleeding brings fines and air to the top, producing a weak laitance layer and — under rebar — voids. Control by reducing water content, increasing fines, using finer cement or SCM, accelerating set slightly, and re-vibrating the top layer before initial set.
Reference: IS 9103:1999 · ACI 309R
B-9
What is the difference between M20, M25, M30, M35 grades and their typical applications?
What is the difference between M20, M25, M30, M35 grades and their typical applications?
The M-prefix is “Mix”; the number is the characteristic 28-day compressive strength in MPa. M20–M25 — residential slabs, lightly-loaded beams, non-structural work. M25–M30 — most RCC residential and commercial frames. M30–M40 — high-rise columns, transfer beams, bridge decks. Mix design — not the M-number alone — controls performance; exposure and durability requirements often govern selection. Try the calculator: Nominal Mix.
Reference: IS 456:2000 Table 2 · IS 10262:2019
B-10
How does temperature affect fresh and hardened concrete properties?
How does temperature affect fresh and hardened concrete properties?
Above 32 °C, fresh concrete loses slump rapidly, the initial set accelerates (danger for long-haul RMC), and water demand rises. Below 5 °C, hydration slows and early strength suffers; below 0 °C, free water freezes and disrupts the paste. Use chilled water / ice in summers and insulated curing / hot-water batching in winter, keeping delivery temperature ideally 18–27 °C. Try the calculator: Concrete Temperature.
Reference: IS 7861 (Part 1) · ACI 305R · ACI 306R
Calculators for this category
All answers live in one searchable FAQ — use the search box to match your exact situation, or jump straight into a category.
Open the full FAQ