Cube Test Register
Compressive-strength register for site/RMC cubes with the IS 456 Table 11 verdict computed per group of 4.
Format ref: CI-CUBE-TEST-REGI
Page ____ of ____
Cube Test Register
IS 516 (Part 1/Sec 1):2018 · IS 456:2000 Cl 15.2, 16.1 & Table 11
Compressive-strength register for site/RMC cubes with the IS 456 Table 11 verdict computed per group of 4.
| Date cast | Structure / Member | Grade | Source (RMC/Site mix) | Slump (mm) | Cube ID 1/2/3 | 7-day (N/mm²) 1/2/3 | 28-day (N/mm²) 1/2/3 | 28-day mean | Table 11 verdict | Remarks |
|---|---|---|---|---|---|---|---|---|---|---|
Note: Sampling rate: minimum 1 sample per 50 m³ (or part) per grade per pour per IS 456 Cl 15.2; each sample = 3 cubes. Group-of-4 verdict per Table 11 (Cl 16.1): mean ≥ fck + 0.825σ (or fck + 3) AND no individual < fck − 3. A failed group routes to Cl 16.4 (investigate) and Cl 17.4 (core test) — never quiet deletion.
Blank register for site use. Acceptance criteria cited from the Indian Standards named above — align with your project specification before contractual use.